Industrial Chamber
Humidity Chamber Manufacturer
Product Brochure
Accuracy (%) | 99 |
Automation Grade | Semi-Automatic |
Frequency (Hz) | 50 |
Phase | 2 |
Voltage (V) | 220 |
Temperature (deg. Celsius) | 5 Degree C to 50 Degree C |
Humidity range | 40% to 95% RH |
- Double walled construction, inner chamber made of SS 304, outer of MS Sheet duly Powder Coated. 75 mm gap between outer & inner chamber is insulated with high efficiency PUF insulation The door is double walled fitted with a leakproof gasket & glass window. Humidity Range. Ambient to 95% +- 5% controlled with imported humidistat / Digital Humidity Controller. Temp. Range: Ambient to 60c Controlled with thermostat / Digital temp. controller. Refrigerated Humidity Chamber Se-109. Specification same as SE-108 but fitted with micro processor based digital temperature & Humidity indicator cum controller. fitted with CFC Refrigeration system with EMERSON Compressor.
Additional Information:
- Item Code: SE-108
Thermal Shock Chambers Manufacturer
Minimum Order Quantity: 1 Piece
Product Brochure
Voltage (V) | 220 V |
Brand | DELHI SCIENTIFIC |
Baskets Transfer Time | 0 TO 5 MINUTE |
Temperature (deg. Celsius) | -60 to +150 |
Relative Humidity (%) | 85 |
Material | Mild Steel |
Air Pressure | 1.00 +/- 0.01 kgf/cm2 |
Usage | 3 chambers thermal shock cabinet |
Description and Application:
As we know that thermal shock occurs when a thermal gradient causes different parts of an object to expand by different amounts. This differential expansion can be understood in terms of stress or of strain, equivalently. At some point, this stress can exceed the strength of the material, causing a crack to form. If nothing stops this crack from propagating through the material, it will cause the object's structure to fail. Normally we use thermal shock test equipment to test how much amount can a product withstand thermal shock.Thermal shock testing exposes products to alternating low and high temperatures to accelerate failures caused by temperature cycles or thermal shocks during normal use. The transition between temperature extremes occurs very rapidly, greater than 15 °C/min.
Working Principle:
there are three chambers used to perform thermal shock testing, high-temperature chamber, low-temperature chamber and test chamber. Sample is placed in the test chamber, more extreme temperature than test temperature can be set in high-temperature chamber and low-temperature chamber. When doing low temperature testing, cold chamber door open, and low-temperature chamber working together with test chamber.When converted into high-temperature test, cold chamber door closed, hot chamber door are opened, and test chamber working together with high-temperature chamber. Conversion of mechanical action (transferring from high temperature to low temperature or low temperature to high temperature) can be completed in less than 1second, and the temperature can be quickly stabilized.During the whole test, test sample is no need to be moved, and without any human intervention.
Additional Information: